The common faults and troubleshooting methods of vibrating fluidized bed dryer in use are as follows:
1. Fault phenomenon: the temperature display is different from the set temperature
Cause analysis: insufficient steam pressure; Steam sensor failure; Electric heating failure; Temperature sensor Fault; The damper of the exhaust duct is too large.
Troubleshooting: check the maintenance steam source; Replace the sensor; Check and repair the electric heater; Replace the sensor;Adjust the damper.
2. Fault phenomenon: the fuselage moves laterally
Cause analysis: the eccentric block of vibration motor is out of synchronization
Troubleshooting: adjust the eccentric block
3. Fault phenomenon: the discharging speed is too fast
Cause analysis: the air volume at the feed end is too large; The included angle of eccentric block of vibration motor is too small
Troubleshooting: adjust the air regulating plate and eccentric block
4. Fault phenomenon: the discharging speed is too slow
Cause analysis: the air volume at the discharge end is too large; The included angle of eccentric block of vibration motor is too large
Troubleshooting: adjust eccentric block and air inlet plate
5. Fault phenomenon: there are large particles at the outlet of cyclone dust collector
Cause analysis: excessive air intake; Excessive air volume of induced draft fan
Troubleshooting: adjust the air inlet plate and induced draft plate